Spectrometers > Industrial Multichannel Spectrometers
Although standard multichannel spectrometers offered by P&P Optica can fulfill many industrial needs, many applications do not require high dynamic range, but a high count of available channels. For this reason, P&P Optica offers spectrometers with up to 144 channels. These systems have some cross-talk among the channels but can perform separate measurements simultaneously. These spectrometers are ideal for situations where many measurements need to be monitored efficiently. In those cases, using a single P&P Optica multichannel spectrometer provides a very cost effective solution.
More information regarding the design and performance of the P&P Optica line of spectrometers can be obtained in the following white paper: Multichannel Imaging Spectrometers.
Available Systems
| Product Name | Spectral range[nm] | Spectral resolution[nm] | Slit length [mm] | # of channels | QntLevl[bit] | Dynanic Range [dB] | |
|---|---|---|---|---|---|---|---|
| From | To | ||||||
| MSPPEC-VIS1-15 | 380 |
740 |
0.7 |
4 |
15 |
16 |
|
| MSPPEC-VIS1-30 | 380 |
740 |
0.35 |
8 |
30 |
12 |
|
| MSPPEC-VIS2-15 | 400 |
780 |
0.7 |
4 |
15 |
16 |
|
| MSPPEC-VIS2-30 | 400 |
780 |
0.35 |
8 |
30 |
12 |
|
| MSPPEC-VIR1-15HS | 455 |
885 |
0.8 |
4 |
15 |
16 |
|
| MSPPEC-VIR1-15LN | 455 |
885 |
0.8 |
4 |
15 |
16 |
|
| MSPPEC-VIR1-30 | 455 |
885 |
0.4 |
8 |
30 |
12 |
|
| MSPPEC-VIR2-15HS | 490 |
955 |
0.9 |
4 |
15 |
16 |
|
| MSPPEC-VIR2-15LN | 490 |
955 |
0.9 |
4 |
15 |
16 |
|
| MSPPEC-VIR2-30 | 490 |
955 |
0.45 |
8 |
30 |
12 |
|
| MSPPEC-VIR4-15 | 575 |
1120 |
1 |
4 |
15 |
16 |
|
| MSPPEC-NIR1-20 | 875 |
1700 |
5 |
5 |
20 |
12 |
|
| MSPPEC-NIR1-30-12B | 875 |
1700 |
2.5 |
8 |
30 |
12 |
|
| MSPPEC-NIR1-30-14B | 875 |
1700 |
2.5 |
8 |
30 |
14 |
|
| MSPPEC-NIR3-20 | 1105 |
2155 |
6.5 |
5 |
20 |
14 |
|
| MSPPEC-NIR3-25 | 1105 |
2155 |
8 |
6.8 |
25 |
16 |
|
Please contact us at sales@ppo.ca for more information about the above systems, higher channel counts or other specifications.
Technical Specifications
| Parameter | Value |
|---|---|
| size | 32cm L x 12cm W x 10 cm H |
| weight | typically <4 kg |
| F/number | F/3 |
| Spectral range (free of second order effects) | 90-95% of an octave in the 380 nm to 2150 nm range |
| Spot diameter | 19 µm @ 1000 nm in 25.4 x 9 mm2 area |
| Spectral resolution (0.024 mm wide pixels) | 0.5 nm @ 400 nm and 2 nm @ 2000 nm |
| Linear dispersion | 90%-95% of an octave per inch |
| Maximum detector size | 25.4 x 12.7 mm |
| Dynamic range of a single 0.024 by 0.024 mm 2 pixel | > 3,000 (typical TE cooled silicon detector) |
| Number of channels | Up to 144, depending on the wavelength, acceptable cross-talk, input fiber and detector |
Please contact us, for more information!